Fiber

Fibers and fiber-optic
components.

Silica, fluoride, chalcogenide and PIR fiber plus hollow waveguide for CO₂ — quoted with the collimator so NA and coating match the window you already specified.

Silica · fluoride · chalcogenide · PIR

Fiber that matches the window.

Silica stops being useful in the mid-IR. We quote silica patchcords for VIS/NIR, fluoride and chalcogenide fiber for MWIR, polycrystalline infrared (PIR) for the long wave, and hollow silica waveguide when the source is a CO2 laser. Connector, NA and wavelength have to be one system — including the collimator on the end.

  • Silica~0.3 – 2.4 µm
  • Fluoride (ZBLAN)~0.4 – 4.5 µm
  • Chalcogenide~1.5 – 6.5 µm (grade-dep.)
  • PIR (AgCl/AgBr)~4 – 18 µm
  • Hollow WGCO2 10.6 µm delivery

Do not do this

A SMA fused-silica collimator on chalcogenide fiber at 4.6 µm is a heat source, not a couple. Match substrate of the collimator to the fiber band — see collimators.

  • ConnectorsSMA905 · FC/PC · FC/APC
  • Core50 – 900 µm typical
  • Length0.5 – 10 m typical

Silica fiber & patchcords

Multimode and single-mode silica for sensing, spectroscopy and 1 µm delivery. High-OH vs low-OH is a real choice around 1.4 µm — say which.

  • NA0.22 typ · specified
  • JacketPVC · acrylate · metal

Mid-IR fiber

Fluoride for 2–4.5 µm (Er:YAG, some QCLs). Chalcogenide glass fiber for 2–6 µm process and sensing. Minimum bend radius is not optional — we will print it on the quote.

  • PowerQuoted per core / λ
  • HandlingBrittle vs silica — plan the strain relief

PIR & hollow waveguide

Polycrystalline AgCl/AgBr fiber for 8–12 µm thermal and spectroscopy. Hollow silica waveguide for CO2 delivery when a transmissive fiber would absorb.

  • PIRKeep dry · light-sensitive
  • HWGLoss vs bend — send path

Collimators & couplers

Connectorised collimators, 1×2 couplers and combiners. AR on the collimator must match the fiber band; see the assemblies page for QCL coupling.

OEM subassemblies

Build-to-print fiber plus window or collimator as one lot. Useful when the instrument already buys our ZnSe or CaF2 windows and needs the delivery path from the same RFQ.

  • TraceabilitySame as coated optics
  • CFM fiberWe can terminate yours

Power handling

CW CO2 into a PIR fiber is a different problem from a 5 mW QCL into chalcogenide. Send average power, pulse width if any, and the launch NA. We will refuse combinations that only melt the connector.

  • LaunchNA · spot · connector
  • CoolingIf the head requires it
RFQ

Wavelength, then the glass.

  • Wavelength (or laser line) and average / peak power
  • Core diameter, NA, length
  • Connectors both ends, or bare / SMA / FC
  • Bend path, temperature, humidity (PIR and salts care)
  • Whether you also need the collimator or a process window

Related

Next

Quote fiber with the optic.

One RFQ for window + fiber + collimator beats three vendors arguing about NA later.