QCL aspheres, MWIR/LWIR camera objectives and fiber collimators quoted from source NA, band and mount — not from a focal-length list.

Illustrative MWIR collimator and QCL bench coupling layout. QCL / MWIR collimator
QCL · thermal · fiber

Collimate the source you actually have.

A catalogue ZnSe sphere is the wrong collimator for a 4.6 µm QCL with fast-axis NA ~0.7 and astigmatism. We quote aspheres, thermal camera objectives and fiber collimators from the source parameters — not from a focal-length list.

  • QCL band3.3 – 12 µm typical
  • Uncooled LWIR8 – 14 µm · Ge / chalcogenide
  • Cooled MWIR3 – 5 µm
  • Fiber VIS/NIRAsphere in FC / SMA housing

QCL aspheres

Molded chalcogenide or diamond-turned ZnSe/Ge aspheres for collimation, focusing and fiber coupling. Fast-axis NA and astigmatism belong on the RFQ — a spherical singlet will leave power on the table.

Thermal camera lenses

Fixed EFL and dual-FOV assemblies for uncooled microbolometers (8–14 µm) and cooled MWIR cameras. f-number, pixel pitch and FPA size set the design — send those, not only “25 mm lens.”

  • f/# typicalf/1.0 – f/1.4 LWIR
  • MountM34 · M34×0.5 · custom

Fiber collimators

Aspheric glass in FC/PC, FC/APC or SMA905 housings for VIS/NIR coupling and collimation. For IR fiber (chalcogenide, PIR) the collimator substrate has to transmit the same band as the fiber.

  • ConnectorFC · SMA905
  • Beam ØQuoted at 1/e2

FTIR crystal optics

KBr and NaCl imaging and condenser elements for FTIR microscopes, plus build-to-print crystal windows. Hygroscopic — packaging and storage notes go on the quote.

Custom optomechanics

Barrel, spacer and retaining-ring sets to print. We can coat and mount customer glass, or supply the optic and the cell together so centration is one lot.

  • CentrationQuoted with mount
  • FinishAl · anodize · custom

Drop-in replacements

If you already have a commercial collimator P/N, send it. We quote equivalent EFL, NA, AR and mount — we do not reverse-engineer a competitor’s coating curve without a measured sample.

  • Best inputP/N + λ + NA
  • BetterA sample to measure
RFQ

Source parameters, not just EFL.

  • Source: QCL line, thermal FPA (pitch, format), or fiber core / NA
  • Desired output: collimated Ø, spot, or FOV
  • Band and coating (line AR vs 8–12 µm BBAR)
  • Mount thread, back focal distance, envelope
  • Operating temperature — germanium transmission falls with heat

Related

Next

Send NA and wavelength.

That pair decides asphere vs sphere, ZnSe vs chalcogenide, and whether the coating is even worth applying.